MODERN TURKISH-UZBEK PATHOMORPHOLOGICAL LABORATORY

MATERIAL SHIPPING INSTRUCTIONS
1. Requirements for Histological Material
Fixation and Transport
Biological material should be shipped in 10% buffered (neutral) formalin.
Transportation should be carried out at room temperature.
Container (vial) containing biological material:
-
It must be hermetically sealed;
-
It must be made of unbreakable material;
-
There should be no signs of leakage.
The ratio between the volume of biological material and the volume of formalin should be at least 1:20. This ratio is necessary for complete tissue fixation and preservation of its morphological structure.
Material Labeling
The label on the vial must clearly state the following information, along with the signature of the responsible person:
-
Date and time the material was taken from the patient;
-
the date and time the material was placed in formalin;
-
patient's last name, first name and, if applicable, father's name;
-
hospital file number or outpatient card number.
The label information on the vial must exactly match the information stated on the guidance form.
General Requirements
The material must have been taken directly from the patient's body and must be labeled according to generally accepted medical standards.
2. Requirements for Histological Blocks and Microscopic Preparations
Requirements for Microscopic Preparations (Preparations on Slides)
The thickness of the microscopic preparation on the slide should not exceed 1 micron (1 µm).
-
If the preparation thickness exceeds 1 µm, it is necessary to prepare the preparation again from the existing paraffin block (if any).
-
If the thickness of the specimen exceeds the permitted limits, it is not possible to perform the examination and digitization process.
When preparing a specimen from an existing paraffin block, it should be considered that the paraffin block may be completely depleted during the sectioning process.
Requirements for Paraffin Blocks
The paraffin block must conform to the FFPE standard (Formalin-Fixed, Paraffin-Embedded) , which includes the following requirements:
-
the material must be fixed in formalin beforehand;
-
Performing standard histological tissue processing procedures;
-
Embedding the tissue sample in paraffin.
The block base should be in the standard histological cassette format. If the block does not conform to the FFPE standard, the block must be re-embedded in paraffin.
Packaging and Liability
The customer is responsible for properly packaging the microscopic preparations and paraffin blocks during shipment via courier service.
Failure to comply with the stated requirements will result in:
-
Accurate and reliable results are not guaranteed;
-
The service is considered rendered and is subject to 100% charge.
.
3. Requirements for Cytological Material
Container and Environment
Cytological material must be sent only in the special cytological vials provided by the Laboratory.

Gynecological material:
-
When using a combination brush, it should be rotated five turns clockwise;
-
When using a Sito brush, it should be rotated twice in one direction.
After the material is collected, the brush is placed inside the vial, the contents of the vial are stirred 5–10 times, the brush tip is left inside the vial, and the cap is tightly closed.
Biological fluids and FNA (Fine Needle Aspiration Biopsy):
-
Less than 3 cm³ (maximum 2 ml) of sample should be placed in the vial;
-
For larger volumes, centrifugation is required:
The collected sample is transferred to a conical tube, shaken 5–10 times, and centrifuged at 2000 rpm for 5 minutes.
After centrifugation, the supernatant is removed and the sediment is transferred into a cytological vial.
Labeling and General Requirements
The label information on the vial must exactly match the information stated on the referral form.
The material must have been taken directly from the patient's body and labeled according to generally accepted medical standards.
INSTRUCTIONS FOR COMPLETING THE REFERRAL FORM
A correctly and fully completed referral form is the foundation of an accurate morphological diagnosis. Insufficient clinical information, labeling errors, or inappropriate fixation conditions may negatively affect the quality of the examination and the turnaround time.
Patient Identification (Mandatory)
-
Full name of the patient
-
Date of birth or age
-
Gender
-
File number / ID
-
Date of specimen collection
Information on the container must be identical to the information on the referral form. Specimens without correct identification will not be processed.
Clinical Information (Critical Importance)
-
Preliminary diagnosis
-
Exact anatomical localization
-
Nature of the process (primary / recurrence / metastasis)
-
Duration of disease
-
Ultrasound, CT, MRI data (if available)
-
Previous treatments (chemotherapy, radiotherapy, hormone therapy, targeted therapy)
❗ Lack of clinical information reduces diagnostic accuracy and may require additional examinations.
Biomaterial Requirements
-
Specimen must be completely immersed in 10% neutral formalin
-
Formalin-to-tissue ratio must be at least 10:1
-
Container must be hermetically sealed
-
Labeling must be clear and permanent
-
Specimen must not be allowed to dry
Information on the container must be identical to the referral form. Specimens without correct identification will not be processed.
Special Requirements for Surgical Material
-
Anatomical orientation of the specimen
-
Marking of resection margins (thread, dye, clips, etc.)
-
Indication of critical margins
-
Purpose of examination (assessment of radicality, margin status, staging)
❗ Unmarked resection margins make it impossible to correctly assess the radicality of the operation.
Additional Requirements for Immunohistochemistry (IHC)
-
Histological report number
-
Clinical purpose of the study
-
List of requested markers
-
Information on previously performed IHC (if any)
-
Common Errors to Avoid
-
Failure to indicate localization
-
Incomplete diagnosis
-
Mismatched patient information
-
Insufficient volume of fixative
-
Missing specimen collection date
-
Absence of physician’s signature
-
Important
The laboratory reserves the right to suspend examination until clinical information is clarified or if fixation conditions are inappropriate. Complete information and adherence to transport standards directly affect the accuracy, turnaround time, and clinical value of the results.
PATIENT INFORMATION
Gynecological material:
-
When using a combination brush, it should be rotated five turns clockwise;
-
When using a Sito brush, it should be rotated twice in one direction.
After the material is collected, the brush is placed inside the vial, the contents of the vial are stirred 5–10 times, the brush tip is left inside the vial, and the cap is tightly closed.
Biological fluids and FNA (Fine Needle Aspiration Biopsy):
-
Less than 3 cm³ (maximum 2 ml) of sample should be placed in the vial;
-
For larger volumes, centrifugation is required:
The collected sample is transferred to a conical tube, shaken 5–10 times, and centrifuged at 2000 rpm for 5 minutes.
After centrifugation, the supernatant is removed and the sediment is transferred into a cytological vial.
Labeling and General Requirements
The label information on the vial must exactly match the information stated on the referral form.
The material must have been taken directly from the patient's body and labeled according to generally accepted medical standards.

MATERIAL PROCUREMENT RULES